Owner`s manual
Table H–2 (Cont.): Standard Console Error Messages (Model 400
and Higher)
Error Message Meaning
?00A0 Initializing system.
1
The console is resetting the system in re-
sponse to a BOOT command.
?00A1 Now updating the EEPROM of node n
1
The console is updating the EEPROM.
?00A6 Console halting after unexpected ma-
chine check or exception.
1
The console executed a Halt instruc-
tion to reset the console state after pro-
cessing an unexpected machine check.
?00A7 RCSR <WD> is set. Local CCA must be
built.
1
When the <WD> bit is set, writes to mem-
ory are disabled. The Model 400 pro-
cessor must then build a CCA in lo-
cal memory. Main memory cannot be writ-
ten to or accessedwith interlocked instruc-
tions.
?00A8 Bootstrap failed due to previous error.
1
The previous attempt to bootstrap the sys-
tem failed.
?00A9 Restart failed due to previous error.
1
The previous attempt to restart the sys-
tem failed.
Node n: ?xxxx Error message ?xxxx was generated on sec-
ondary processor n and was passed
to the primary processor to be dis-
played.
1
No numbered prefix appears with these messages in English language mode. These num-
bers are used for these messages in International mode.
Console Error Messages (Model 400 and Higher) H–11