Owner`s manual

Table H–2 (Cont.): Standard Console Error Messages (Model 400
and Higher)
Error Message Meaning
?0077 CCA not accessible or corrupted. Attempt to find the console communi-
cations area (CCA) failed. The con-
sole then builds a local CCA, which does
not allow for interprocessor communica-
tion.
?0078 Vector module configuration error at node
n
The console detected a vector module con-
figuration error. Problem can be that the
vector node number is not one greater
than the scalar CPU or that the mod-
ule to the left of a vector proces-
sor is not a memory module.
?0079 Vector synchronization error. The console could not synchronize with
the vector processor on a console en-
try. The Busy bit in the Vector Pro-
cessor Status Register remained set af-
ter a timeout, or a vector processor er-
ror occurred.
?007A No vector module associated with CPU
at specified node.
No vector module is in the slot to the left
of the specified CPU, or the VIB cable ei-
ther is not attached or is bad.
?007B An error occurred while accessing the vec-
tor module.
Attempt to access VCR, VLR, or VMR reg-
isters failed.
?007C I/O adapter configuration error at node
n
The I/O adapterat node n isconfigured im-
properly.
?007D Vector module is disabled—check KA64A
revision at XMI node n
The vector module is attached to a KA64A
module that is not at the revision level re-
quired.
?0083 Loading system software.
1
The console is attempting to load the oper-
ating system in response to a BOOT com-
mand, power-up, or restart failure.
?0084 Failure.
1
An operation did not complete success-
fully. Should be issued with another mes-
sage to clarify failure.
?0085 Restarting system software.
1
The console is attempting to restartthe in-
memory copy of the operating sys-
tem following a power-up or serious er-
ror.
1
No numbered prefix appears with these messages in English language mode. These num-
bers are used for these messages in International mode.
H–10 VAX 6000 Series Owner’s Manual