Owner`s manual
Table H–2 (Cont.): Standard Console Error Messages (Model 400
and Higher)
Error Message Meaning
?0041 Specified node is not a bus adapter. A command to access a VAXBI node spec-
ified an XMI node that was not a bus
adapter.
?0042 Invalid terminal speed. The SET TERMINAL command speci-
fied an unsupported baud rate.
?0043 Unable to initialize node. The INITIALIZE command failed to re-
set the specified node.
?0044 Processor is not enabled to BOOT or
START.
As a result of a SET CPU/NOENABLE
command, the processor is disabled from
leaving console mode.
?0045 Unable to stop node. The STOP command failed to halt the
specified node.
?0046 Memory interleave set is
inconsistent: n n ...
The listed nodes do not form a valid mem-
ory interleave set. One or more
of the nodes might not be a mem-
ory array or might be of a differ-
ent size, or the set could contain an in-
valid number of members. Each listed ar-
ray that is a valid memory will be config-
ured uninterleaved.
?0047 Insufficient working memory for nor-
mal operation.
Less than 256 Kbytes per processor of
working memory were found. There is in-
sufficient memory for the console to func-
tion normally or for the operating sys-
tem to boot.
?0048 Uncorrectable memory errors—long mem-
ory test must be performed.
A Model 400 memory array contains
an unrecoverable error. The con-
sole must perform a slow test to lo-
cate all the failing locations.
?0049 Memory cannot be initialized. The specified operation was attempted
and prevented.
?004A Memories not interleaved due to
uncorrectable errors:
The listed arrays would normally have
been interleaved (by default or explicit re-
quest). Because one or more of them con-
tained unrecoverable errors, this inter-
leave set will not be constructed.
?004B Internal logic error in console. The console encountered a theoreti-
cally impossible condition.
H–6 VAX 6000 Series Owner’s Manual