Owner`s manual

Table H–2 (Cont.): Standard Console Error Messages (Model 400
and Higher)
Error Message Meaning
?0033 Z connection successfully started. You have requested a Z connection to a
valid node.
?0034 Specified target already has a Z
connection.
The target node was the target of a previ-
ous Z connection that was improperly ter-
minated. Reset the system to clear this
condition.
?0036 Command too long. The command length exceeds 80 charac-
ters.
?0037 Bad explicit interleave list configur-
ing all arrays uninterleaved.
The list of memory arrays for ex-
plicit interleave includes no nodes that
are actually memory arrays. All ar-
rays found in the system are config-
ured.
?0039 Console patches are not usable. The console patch area in EEPROM
is corrupted or contains a patch revi-
sion that is incompatible with the con-
sole ROM.
?003B Error encountered during I/O
operation.
An I/O adapter returned an error status
while the console boot primitive was per-
forming I/O.
?003C Secondary processor not in console mode. The primary processor console needed to
communicate with a secondary proces-
sor, but the secondary processor was not
in console mode. STOP the node or re-
set the system to clear this condi-
tion.
?003D Error initializing I/O device. A console boot primitive needed to per-
form I/O, but could not initialize the I/O
adapter.
?003E Timeout while sending message to
secondary processor.
A secondary processor failed to re-
spond to a message sent from the pri-
mary. The primary sends such mes-
sages to perform console functions on sec-
ondary processors.
?003F Microcode power-up self-test failed
in REX520.
Model 400 CPU chip failed its mi-
crocoded self-test.
?0040 Key switch must be at "Update" to
update EEPROM.
A SET command was issued, but the
key switch was not set to allow up-
dates to the EEPROM.
Console Error Messages (Model 400 and Higher) H–5