Owner`s manual

Table H–2 (Cont.): Standard Console Error Messages (Model 400
and Higher)
Error Message Meaning
?0025 Checksum did not match. The checksum calculated for a block of X
command data did not match the check-
sum received.
?0026 Halted. The processor is currently halted.
?0027 Item was not found. The item requested in a FIND com-
mand could not be found.
?0028 Timeout while waiting for characters. The X command failed to receive a full
block of data within the timeout pe-
riod.
?0029 Machine check accessing memory. Either the specified address is not im-
plemented by any hardware in the sys-
tem, or an attempt was made to write
a read-only address, for example, the ad-
dress of the 33rd Mbyte of mem-
ory on a 32-Mbyte system.
?002A Unexpected machine check or
interrupt.
A valid operation within the console
caused a machine check or interrupt.
?002B Command is not implemented. The command is not implemented by this
console.
?002C Unexpected exception. An attempt was made to examine ei-
ther a nonexistent IPR or an unimple-
mented register in RSSC address range
(20140000—20140800).
?002D For Secondary Processor n. This message is a preface to sec-
ond message describing some error re-
lated to a secondary processor. This mes-
sage indicates which secondary proces-
sor is involved.
?002E Specified node is not an I/O adapter. The referenced node is incapable of per-
forming I/O or did not pass its self-
test.
?0030 Write to Z command target has timed out. The target node of the Z command is not
responding.
?0031 Z connection terminated by ^P. A CTRL/P was typed on the key-
board to terminate a Z command.
?0032 Your node is already part of a Z
connection.
You cannot issue a Z command while exe-
cuting a Z command.
H–4 VAX 6000 Series Owner’s Manual