Owner`s manual
6. * Remote service link established
7. * Reading boot image from remote node
?010F Failed to receive image from remote server
8. * Passing control to transfer address
Disk Boot Status and Error Boot Messages
1. [Start Boot]
?0046 Specified node is not an I/O adapter
?0100 Specified adapter failed selftest
?010A Illegal adapter specified for disk boot
2. * Initializing adapter
?0119 Failure to initialize specified adapter
3. * Specified adapter initialized successfully
4. * Connecting to boot disk
?0117 Specified unit offline
?0118 Specified unit offline—Unit unknown, online to another
controller or port disabled via A,B switches
?010E Specified unit offline — No media mounted or disabled via
RUN/STOP switch setting
?0116 Specified unit is inoperative
?0103 Drive error detected—aborting
?0102 Controller error detected—aborting
?0114 Serious exception reported—aborting
5. * Reading bootblock from disk
?0117 Specified unit offline
?0118 Specified unit offline—Unit unknown, online to another
controller or port disabled via A,B switches
?010E Specified unit offline—No media mounted or disabled via
RUN/STOP switch setting
?0116 Specified unit is inoperative
?0103 Drive error detected—aborting
?0102 Controller error detected—aborting
?0114 Serious exception reported—aborting
6. * Passing control to transfer address
1–22 VAX 6000 Model 500 Mini-Reference