Table 1–12 (Cont.): Standard Console Error Messages
Error Message Meaning
?0106 Filename cannot contain nested blanks or
tabs.
For filename specified in a MOP boot.
?0107 Filename can be no longer than 16 char-
acters.
For filename specified in a MOP boot.
?0111 Microcode power-up self-test failed in
DC595.
CPU chip failed its microcoded self-
test.
?011E Uncorrectable memory errors discovered -
long memory test must be performed on node n
Memory array in node n contains an un-
correctable error. The console must per-
form a fulltest to locate all the failing loca-
tions.
?0120 Unsupported memory module found, will
not be configured.
One or more MS62A memory mod-
ules are installed but will not be used.
Only MS65A memory modules are com-
patible with Model 500.
?0121 Patch command no longer implemented—
use the Diagnostic utility EVUCA.
An invalid PATCH command was is-
sued; use the EVUCA program to up-
date the EEPROM.
?8003 Loading system software.
1
The console is attempting to load the oper-
ating system in response to a BOOT com-
mand, power-up, or restart failure.
?8004 Failure.
1
An operation did not complete success-
fully. Should be issued with another mes-
sage to clarify failure.
?8005 Restarting system software.
1
The console is attempting to restart thein-
memory copy of the operating sys-
tem following a power-up or serious er-
ror.
?8020 Initializing system.
1
The console is resetting the system in re-
sponse to a BOOT command.
?8027 Console halting after unexpected ma-
chine check or exception.
1
The console executed a Halt instruc-
tion to reset the console state after pro-
cessing an unexpected machine check.
?00A7 RCSR <WD> is set. Local CCA must be
built.
When the <WD> bit is set, writes to mem-
ory are disabled. The Model 400 pro-
cessor must then build a CCA in lo-
cal memory. Main memory cannot be writ-
ten to or accessed with interlocked instruc-
tions.
1
No numbered prefix appears with these messages in English language mode. These num-
bers are used for these messages in International mode.
1–20 VAX 6000 Model 500 Mini-Reference