Owner`s manual
Table 1–12 (Cont.): Standard Console Error Messages
Error Message Meaning
?0054 EEPROM revision mismatch.
Secondary processor has revision x.xx/y.yy.
A secondary processor has a differ-
ent revision of EEPROM or has a dif-
ferent set of EEPROM patches in-
stalled.
?0055 Failed to locate EEPROM area. The EEPROM did not contain a set of
data required by the console. The EEP-
ROM may be corrupted.
?0056 Console parameters on secondary proces-
sor do not match primary.
The console parameters are not the same
for all processors .
?0057 EEPROM area checksum error. A portion of the EEPROM is corrupted.
It may be necessary to reload the EEP-
ROM from the TK tape drive.
?0058 Saved boot specifications on secondary
processor do not match primary.
The saved boot specifications are not the
same for all processors.
?0059 Invalid unit number. A BOOT or SET BOOT command speci-
fied a unit number that is not a valid hex-
adecimal number between 0 and FF.
?005A System serial number mismatch.
Secondary processor has xxxxxxxx.
The indicated serial number of a sec-
ondary processor does not match that of
the primary.
?005B Unknown type of boot device. The console program does not have a boot
primitive to support the specified type
of device or the device could not be ac-
cessed to determine its type.
?005C No HELP is available. The HELP command is not supported
when the console language is set to Inter-
national.
?005D No such boot spec found. The specified boot specification was not
found in the EEPROM.
?005E Saved boot spec table full. The maximum number of saved boot spec-
ifications has already been stored.
?005F EEPROM header version mismatch. Processors have different versions of EEP-
ROMs.
?0061 EEPROM header or area has bad
format.
All or part of the EEPROM contains in-
consistent data and is probably cor-
rupted. Reload the EEPROM from the TK
tape.
?0062 Illegal node number. The specified node number is invalid.
Console Operation 1–17