Table 1–12 (Cont.): Standard Console Error Messages
Error Message Meaning
?002D For Secondary Processor n. This message is a preface to sec-
ond message describing some error re-
lated to a secondary processor. This mes-
sage indicates which secondary proces-
sor is involved.
?002E Specified node is not an I/O adapter. The referenced node is incapable of per-
forming I/O or did not pass its self-
test.
?0030 Write to Z command target has timed out. The target node of the Z command is not
responding.
?0031 Z connection terminated by ^P. A CTRL/P was typed on the key-
board to terminate a Z command.
?0032 Your node is already part of a Z
connection.
You cannot issue a Z command while exe-
cuting a Z command.
?0033 Z connection successfully started. You have requested a Z connection to a
valid node.
?0034 Specified target already has a Z
connection.
The target node was the target of a previ-
ous Z connection that was improperly ter-
minated. Reset the system to clear this
condition.
?0036 Command too long. The command length exceeds 80 charac-
ters.
?0037 Explicit interleave list is bad.
Configuring all arrays uninterleaved.
The list of memory arrays for ex-
plicit interleave includes no nodes that
are actually memory arrays. All ar-
rays found in the system are config-
ured.
?0039 Console patches are not usable. The console patch area in EEPROM
is corrupted or contains a patch revi-
sion that is incompatible with the con-
sole ROM.
?003B Error encountered during I/O
operation.
An I/O adapter returned an error status
while the console boot primitive was per-
forming I/O.
?003C Secondary processor not in console mode. The primary processor console needed to
communicate with a secondary proces-
sor, but the secondary processor was not
in console mode. STOP the node or re-
set the system to clear this condi-
tion.
1–14 VAX 6000 Model 500 Mini-Reference