Operator`s manual

not substitute other covers as they may not meet the re-
quired specifications.
Operating the system without the slot covers has the
following consequences:
The system may overheat due to inadequate air cir-
culation.
The system will not comply with FCC and VDE re-
quirements for electrostatic shielding, and may pro-
duce electrical interference that affects other equip-
ment.
The system is susceptible to electrical interference
or damage from external sources.
2.6.1 Connecting Terminals and Serial Printers
You can connect up to 16 terminals and/or serial printers for each CXA16
or CXB16 module installed in the system. If the site has been prepared
properly, the lines for the additional terminals and printers are clearly
labeled, and terminate near the system.
You do not connect the terminals and printers directly to the system,
but to a cable concentrator (H3104), which has connections for up to
eight terminals and printers. You then connect the cable concentrator
to the system with a BC16D cable. Two H3104 cable concentrators and
two BC16D cables for each CXA16 module are shipped with the CXA16
module.
Connect the additional terminals and printers as follows:
1. Find the H3104 cable concentrator and BC16D cable (see Fig-
ure 2–12.
2–26 Installation