Setting Controls on the System Control Panel (SCP)
Check the settings on the SCP:
Halt button—This button is located on the SCP, to the left of the
ISEs. The Halt button should be in the out position.
Setting Controls on the Console Bulkhead Assembly
Check the settings on the console bulkhead assembly (see Figure 2–11):
Power-Up mode switch This three-position rotary switch
determines how the system responds at power-up. The factory
setting is run mode (right pointing arrow). Set the switch to
the language inquiry mode (the face profile) before you power
on the system the first time.
Baud rate select switch This switch (see Figure 2–11) sets
the system baud rate to match that of the console terminal.
The factory setting is position 5 (9600). Set the console
terminal baud rate to 9600. The system and the console
terminal must be set to the same baud rate to communicate.
Break enable/disable switch When this switch is pushed
back (down or O position), breaks are disabled. When the
switch is forward (up or | position), breaks are enabled. The
factory setting is break disabled (O). Leave the switch set to
disable while you start the system for the first time, and run
diagnostic firmware to test the system. Then set the switch
to enable (|). With break enabled, the system automatically
enters console mode when powered on, as indicated by the
console prompt (>>>) on the console.
You are now ready to connect additional devices to the system.