Operator`s manual
The console bulkhead assembly contains the following controls and
indicators:
Power-Up mode switch — This three-position rotary switch
determines how the system responds at power-up:
Language inquiry mode (the position indicated by a
profile of a face) causes the system to display a lan-
guage selection menu at power-up if your console ter-
minal supports multiple languages. Also, if a default
boot device has not been selected, this mode causes the
system to issue a list of bootable devices and prompts
you to select a device from the list. Once a device is
selected, the system autoboots from that device each
time you turn it on.
Run mode (the position indicated by an arrow) is the
normal operating setting.
Loop back test mode (the position indicated by a T in a
circle) causes the system to run loopback tests on the
console serial line at power-on. This setting requires
special loopback connectors and is for Digital Customer
Services use only.
Baud rate select switch — This switch sets the system baud
rate to match that of the console terminal. The factory setting
is position 5 (9600).
Modified modular jack (MMJ) — This console terminal connec-
tor provides the connection for the console terminal.
Light-emitting diode (LED) — This display shows the testing
sequence during power-up.
System Overview 1–15