Technical data

5
VAX/VAXserver 4000-300, -400, and -500
Conversion
This chapter describes how to convert from a VAX 4000-300, -400, and -500
system to a VAX 4000-400, -500, and -600 system; from a VAXserver 4000-300,
-400, and -500 system to a VAXserver 4000-400, -500, and -600 system; or from
a VAXserver 4000-300 system to a VAX 4000-300 system. To upgrade these
systems, use one of the conversion kits: 670XR-AA, 675XR-XX, 680XR-XX, or
690XR-XX. The VAXserver 4000-300 system uses the 670XR-AA conversion kit.
Caution
Wear the antistatic wrist strap and use the antistatic mat when
removing or installing the KA670, KA675, KA680, and KA690 modules.
Note
The L4001-type memory modules will not function with the KA675-XX,
KA680-XX, or KA690-XX CPU modules. When a KA670 CPU is
removed and the system is converted to a KA675, KA680, or KA690
system, memory must be upgraded to L4004-type memory.
5.1 Summary of Conversion
The tasks required to convert from a VAX/VAXserver-300, -400, and -500
system to a VAX/VAXserver 4000-300, -400, -500, and -600 system, are
summarized as follows. To begin the actual conversion, go to Section 5.3.
1. Have the customer back up the system software.
2. Run diagnostics to verify system operation.