This chapter describes how to convert from a VAXserver 4000-200 system to a
VAX 4000-200 system using a 660XR-XX conversion kit.
4.1 Summary of Conversion
The tasks required to convert from a VAXserver 4000-200 system to a VAX
4000-200 system, are summarized as follows. To begin the actual conversion,
go to Section 4.2.
1. Have the customer back up the system software.
2. Run diagnostics to verify system operation.
3. Unpack and inventory the conversion kit.
4. Remove CPU I/O panel cables.
5. Remove CPU I/O panel.
6. Disconnect the CPU module cables.
7. Remove the old CPU module.
8. Install the new KA660-AA (M7626) CPU module.
9. Reconnect the CPU module cables.
10. Reinstall the CPU I/O panel.
11. Reconnect the CPU I/O panel cables.
12. Install the CPU label to the I/O panel.
13. Install the conversion label.
VAXserver 4000-200 Conversion 4–1