6. Remove the CPU I/O cover cables.
7. Remove the CPU I/O panel.
8. Remove the module cover from the KFQSA module. Remove the module
covers from the memory slots, if memory needs to be upgraded.
9. Disconnect the CPU memory cable.
10. Remove the old CPU module.
11. Install the new KA660 (M7626) CPU module.
12. Upgrade the old memory modules to MS650-BA/BB, if necessary.
13. Reroute the internal DSSI cable, if applicable.
14. Install the DSSI handle.
15. Reconnect the cables to CPU and memory modules.
16. Install the new H3602 CPU I/O panel and reconnect the panel cables.
17. Reinstall the memory module covers.
18. Install the module cover labels.
19. Install the OCP and media faceplate.
20. Install the front panel.
21. Run diagnostics to verify system operation.
22. Install the new medallion and labels.
23. Have the customer verify that the system software boots and operates
correctly.
24. Complete the forms in Appendix A.