Technical data
3.4.1 Removing an RZ or an RF-Series ISE
Use the following instructions to remove an RF-series ISE and refer to
Figure 3–6.
CAUTION: Static electricity can damage integrated circuits. Use the wrist
strap and antistatic mat found in the antistatic kit (29–26246–00) when you
work with the internal parts of a computer system.
Handle the ISEs with care. Dropping or bumping an ISE can damage the
disk surface. Carry or hold the ISEs by their metal brackets to avoid damage
to the drive module.
Figure 3–4: Removing an ISE Front Panel ID Plug
MLO-004045
Bus Node
ID Plug
1. Remove the Bus I.D.Plug Figure 3–4.
2. Loosen the single captive Phillips screw that secures the ISE front panel
(Figure 3–6A).
3. Separate the ISE front panel and unplug the cable from the enclosure
and lay it aside (RF–series only).
BA430/BA440 FRU Removal and Replacement 3–9