Technical data

H3605 I/O panel
H7874 power supply
Fan tray
3.3.1 M9715–YA Interface Module (BA430 Enclosure Only)
The M9715–YA interface module, is located to the left of the H7874 power
supply. This module is positioned in a dedicated to the first backplane
slot, slot 0. To remove the M9715 module, first remove the H3605 SCSI
connector panel from slot 0. The M9715 module is installed in slot 0 under
the H3605 cover.
3.3.2 M7638–YA I/O Module (BA430 Enclosure Only)
The M7638–YA I/O module is located in slot 1 next to the M9715 two bus
slots away from the H7874 power supply. To remove the M7638 module,
first remove the H3602 CPU cover panel from over slots 1 and 2. The
M7638 I/O module is installed in slot 1 under the H3602 CPU cover panel.
3.4 Replacing RF and RZ Series Integrated Storage
Elements (ISE)
NOTE: The illustrations in this section show the BA440 enclosure.
Duplicating the same basic illustrations for the BA430 enclosure is
unnecessary. The removal procedures are the same for both enclosures.
This section describes how to replace RF and RZ-series ISE’s. In addition,
procedures are provided to replace the following individual FRUs that
comprise the integrated storage element:
ISE Bus I.D. plug
ISE front panel
ISE front panel module (RF-series only)
Interface card assembly (RF-series only)
Remote front panel cable (RF-series only)
For information on troubleshooting strategy, error analysis, and RZ and
RF-series diagnostics, as well as information on removal and replacement
of the drive module and head-disk assembly (HDA), refer to the appropriate
integrated storage element service guide. Replacing the drive module does
not require removal of the ISE bracketry.
3–8 BA430/BA440 Enclosure Maintenance