Technical data
The temperature warning indicator shows that the system’s internal
temperature is approaching a level that may cause system components to
overheat. If the internal temperature raises unacceptably, you will hear an
audible pulsing sound and the temperature warning indicator will flash.
The sound and visual marker are warning you of a possible temperature
condition, before the system automatically shuts down. This feature allows
you time to take corrective action. You could lower the room’s temperature,
remove airflow obstructions, or perform an orderly system shutdown to
prevent data loss.
The green DC OK indicator shows that the voltages are within the correct
operating range. If the DC OK indicator is not lit when the system power
is on, then a problem exists with the power supply.
Below the DC ok indicator are the Halt and Restart button indicators. The
Halt button is a two-position button. When pressed, the system halts and
the Halt LED is lit as the console mode prompt (>>>) is displayed on the
terminal screen. Before you can enter console commands, press the Halt
button again to return it to the out position. Now you can enter console
commands. If by mistake you press the Halt button, type C and press
Return to continue.
CAUTION: Pressing the Halt button halts the system unconditionally, in
spite of setting the Break Enable/Disable switch on the console module.
The Run/Restart button/indicator is located below the Halt button indicator.
When pressed, the system returns to a run or reboot condition. If you have
specified a device as the boot device and if the Break Enable/Disable switch
is set to Disable, the system will reboot the system software.
1.9 Enclosure Modification
A system manager may request the following modifications to the SCP and
fan speed control.
Switches located on the SCP board can be used to disable the SCP button
functions. For example, if you were going to leave the access doors open
when training new people on the system this could prevent accidental
system shutdown.
When a system is located in an area where fan noise is more tolerable
to users, the speed of the fans can be increased. This action would take
advantage of a potential increase in system reliability, because the system
components function in a cooler environment.
BA430/BA440 Enclosure Description 1–13