Specifications

6-1.1
Proprietary and Confidential
MOD
UDC
ATTEN
DETECTOR
PA MODULE
PAB
FILTER
FWD REF
ANTENNA
FRONT
PANEL
µC
FWD POWER REF (FPR)
OR RAISE/LOWER Buttons
DAC
ADC
ANALOG
LINES V
*
AMP CTRL
* 0 dBm at this point during power cal when at model number power. Use pads as needed.
mC (micro) compares FPR to current power level then raises or lowers UDC attenuator
Power increases during ramp start are done in 50% increments (1 per sec.) until current power is
within a few watts of Forward Power Reference value then stops.
RF ATTEN DAC value found on calibration screen. Values > 500 (HEX) indicate a problem.
Power increase should be evident at DAC level >200 (HEX).
DAC level is controlled directly in MANUAL mode of operation.
LPU
VAX ALC Control
Error Voltage
Digital
Pot.
Raise
Lower
Pad