Specifications

4-1.15
Proprietary and Confidential
LPU USER REMOTE CONNECTOR
User Remote - 25 Pin Female
Signal Direction Description Control I/O
Assignment
1 Forward Power Output 0 4.096VDC output representing Forward power level Analog Output 0
2 Reflected Power Output 0 4.096VDC output representing reflected power level Analog Output 1
3 Spare Analog In 1 Input Analog Input 2
4 Spare Analog In 2 Input Analog Input 3
5 +12Vdc Output +12Vdc, 200mA max
6 GND Ground
7 GND Ground
8 GND Ground
9 GND Ground
10 GND Ground
11 Alarm 0 Common Alarm 0 Relay Common
12 Alarm 0 Normally Closed Alarm 0 Relay Normally Closed (Faulted) Position
13 Alarm 0 Normally Open Alarm 0 Relay Normally Open (Non-Faulted) Position
14 Alarm 1 Common Alarm 1 Relay Common
15 Alarm 1 Normally Closed Alarm 1 Relay Normally Closed (Faulted) Position
16 Alarm 1 Normally Open Alarm 1 Relay Normally Open (Non-Faulted) Position
17 Alarm 2 Common Alarm 2 Relay Common
18 Alarm 2 Normally Closed Alarm 2 Relay Normally Closed (Faulted) Position
19 Alarm 2 Normally Open Alarm 2 Relay Normally Open (Non-Faulted) Position
20 Alarm 3 Common Alarm 3 Relay Common
21 Alarm 3 Normally Closed Alarm 3 Relay Normally Closed (Faulted) Position
22 Alarm 3 Normally Open Alarm 3 Relay Normally Open (Non-Faulted) Position
23 Alarm 4 Common Alarm 4 Relay Common
24 Alarm 4 Normally Closed Alarm 4 Relay Normally Closed (Faulted) Position
25 Alarm 4 Normally Open Alarm 4 Relay Normally Open (Non-Faulted) Position
This connector is on the rear of the LPU. It can be used for remote control and monitoring on
standalone transmitters (non racked systems without TCU’s).