Specifications
2-5.5
Proprietary and Confidential
FRONT PANEL CONTROL BOARD SCHEMATIC 801-0203-361
PAB Cal Pots
Remote
Enable/Disable
Disable forces
PAB on.
PS Voltage
Adjust (set to
50V at factory).
Lower voltage
means lower
output power.
Resets Internal Faults
Pressing this reset will turn
on all modules in PAB
without turning off active
modules.
ON button for transmitter
will reset all modules in
transmitter by first turning
them off. This takes
transmitter off-air for a few
seconds.
Remove
Jumper to
Keep PAB OFF
(was a switch
in DMB)