Technical data
SDA Description
CONTINUE
VAX-11/750
The following code causes a system failure on a VAX-11/750. On this processor,
the HALT command is a NOP; a Ctrl/P automatically halts the processor.
$
Ctrl/P
>>> H
>>> EP
>>> E/I 0
>>> E/I +
>>> E/I +
>>> E/I +
>>> E/I +
>>> D/G F FFFFFFFF
>>> D P 41F0000
>>> C
MicroVAX 3400/3600/3900 Series, VAXstation/MicroVAX 3100,
VAXstation/MicroVAX 2000, MicroVAX II, and VAX 4000 Series
To force a crash of a MicroVAX, you must first halt the processor. (After you halt
the processor, press the HALT button again so that it is popped out and is not
illuminated.) Then, issue the following console commands:
>>> E PSL
>>> E/I/N:4 0
>>> D PC FFFFFFFF
>>> D PSL 41F0000
>>> C
VAX-11/730
The following console commands cause a system failure on a VAX-11/730. Ctrl/P
automatically halts the processor.
$
Ctrl/P
>>> H
>>> E PSL
>>> E/I/N:4 0
>>> D PC FFFFFFFF
>>> D PSL 1F0000
>>> C
SDA–34