User`s guide

Power and Cooling Systems
4.1.1 Input Power
The input power is five-wire (three-phase AC, neutral, and ground).
208V 60 Hz AC enters the H405-E AC power controller. 380V 50 Hz AC
inputs the H405-F AC power controller and then enters the high-voltage
autotransformer, which reduces the voltage to 208.
The H405 AC power controllers suppress conducted emissions. The AC
power controller has a contactor that closes when the control panel upper
key switch is in any position except "0," allowing AC power to the H7206-
B, and opens if the cabinet’s temperature sensor detects an excessive
temperature.
4.1.2 H7206-B Power and Logic Unit
The H7206-B:
Rectifies the three-phase power into 300V DC for the DC-to-DC power
regulators
Develops regulated +14V DC for both internal use and the DC-to-DC
power regulators
Develops 110 watts of 24V DC for the cooling system blowers and its
own internal fan
Controls the interface between power regulators
Controls the interface between the power regulators and the rest of
the system
The nine LEDs in the upper right corner of the H7206-B are explained
in Table 4–1. The green +14V bias LED lights to indicate when the bias
supply on the fan/power module is working.
Table 4–1 H7206-B LEDs
LED Color Meaning
9 Red Fault (airflow, interlock, overtemperature)
8 Red XMI-1 module in XMI-2 card cage
7 Red H7214 or H7242 installed incorrectly
6 Red VAXBI—H7214 fault
5 Red VAXBI—H7215 fault
4 Red XMI—H7242 fault
3 Red XMI—H7214 fault
2 Red XMI—H7215 fault
1 Green +14V logic bias is okay