Installation guide

Diagnostics and Utilities 8-5
1
When the system powers up, self-test runs. Verify that all tests have
passed by checking the results in the self-test display.
2
Use the show configuration command to determine the self-test
status for the I/O adapter through which loading will be performed.
For RRD42 CD drive booting, check the status of the KZMSA I/O
adapter. For InfoServer booting, check the status of the DEMNA or
DEMFA I/O adapter. Determine the mnemonic assigned to the I/O
adapter associated with the target boot device.
3
Check the console load device hardware. For VAX 10000 systems,
check the Ethernet adapter by examining the self-test results and the
green test light on the module, which reports the results of the Ether-
net loopback test.
4
Using the mnemonic in step 2, use the show network for the VAX
10000 (such as show network demna0) or a show device command
for the DEC 10000 to obtain the assigned name of the target device.
5
Load and run the operating system.
6
Verify the system under the installed operating system.
For more information:
Console Reference Manual