Installation guide

Diagnostics 4-7
Example 4-5 Test Command — Detection of Memory Data
Compare Error
>>> set d_report full
>>> test ms7aa*
Configuring system...
Testing ms7aa*
Type Ctrl/C to abort
Starting memory exerciser, running on ka7aa0 (id #77)
Starting memory exerciser, running on ka7aa1 (id #78)
Starting memory exerciser, running on ka7aa2 (id #79)
*** Hard Error - Error #23 on FRU: ka7aa0
Data compare error
ID Program Device Pass Hard/Soft Test Time
-------- -------- --------------- -------- --------- ---- --------
00000078 mem_ex memory 433 1 0 4 10:23:51
Expected value: FFFFFFE0
Received value: FFF7FFE0
Failing addr: 047C87C8
*** End of Error ***
Testing aborted - halt-on-error selected...
Stopping memory exerciser on ka7aa1 (id #77)
Stopping memory exerciser on ka7aa2 (id #79)
Done testing...
>>>