User`s guide
G
Error Messages
The error messages issued by the KA52/53/54 firmware fall into three
categories: halt code messages, VMB error messages, and console messages.
G.1 Machine Check Register Dump
Some error conditions, such as machine check, generate an error summary
register dump preceding the error message. For example, examining a
nonexistent memory location results in the following display:
>>>e/p/l 20000000
MESR=00006000 MEAR=08406010 MMCDSR=01111000 MOAMR=00000000
CESR=80000200 CMCDSR=0000C108 CSEAR1=00000000 CSEAR2=00000000
CIOEAR1=00000000 CIOEAR2=00000000 CNEAR=00000000 ICSR=00000001
PCSTS=FFFFF800 PCADR=FFFFFFF8 TBSTS=C00000E0 TBADR=F5755754
NESTS=00000000 NEOADR=E014066C NEOCMD=8000F005 NEICMD=000003FF
NEDATHI=FFFFFFFF NEDATLO=FF7F9FFF CEFSTS=0001920A CEFADR=E0000000
BCETSTS=000003E0 BCETIDX=FFFFFFE0 BCETAG=FFFFFE00 BCEDSTS=00000F00
BCEDIDX=001FFFF8 BCEDECC=00000000 CBTCR=00004000 DSER=00000080
QBEAR=00000000 DEAR=00000000 IPCR0=0000 ECR=0000008A
SCSICSR4=00 SCSICSR6=C0 SCSICSR5=00
?7D MACHINE CHECK 80060000 00000000 20048C68 20048C59 20048C55 40110080
>>>
G.2 Halt Code Messages
Except on power-up, which is not treated as an error condition, the following
halt messages are issued by the firmware whenever the processor halts
(Table G–1).
For example, if the processor encounters a HALT instruction while in kernel
mode, the processor halts and the firmware displays the following before
entering console I/O mode:
?06 HLT INST
PC = 800050D3
Error Messages G–1