User`s guide

System Troubleshooting and Diagnostics
5.7 Using Loopback Tests to Isolate Failures
Table 5–5 Loopback Connectors for Common Devices
Device Module Loopback Cable Loopback
CXA16/CXB16 H3103 + H8572
1
CXY08 H3046 (50-pin) H3197 (25-pin)
DIV32 H3072
DPV11 12–15336–10 or H325 H329 (12–27351–01)
DRQB3 17–01481–01 (from port 1 to
port 2)
DRV1W 70–24767–01
DZQ11 12–15336–10 or H325 H329 (12–27351–01)
Ethernet
2
––
IBQ01 IBQ01–TA
IEQ11 17–01988–01
KA52 H3103 H3103 + H8572
KFQSA DSSI terminators
KMV1A H3255 H3251
KZQSA 12–30552–01
LPV11 12–15336–11
1
Use the appropriate cable to connect transmit-to-receive lines. H3101 and H3103 are double-
ended cable connectors.
2
For ThinWire, use H8223–00 plus two H8225–00 terminators. For standard Ethernet, use
12–22196–02.
5–64 System Troubleshooting and Diagnostics