User`s guide
System Troubleshooting and Diagnostics
5.3 Power-On Self-Test (POST) and ROM-Based Diagnostic (RBD) Failures
Table 5–4 (Cont.) KA52/53/54 Console Displays as Pointers to FRUs
On
Error
Hex
LED
Normal
Console
Display
Default
Action on
Error
Failing
Test
Number Test Description FRU
1
Power-Up Tests (Script A1)
B 18 Cont 9A INTERACTION 1
7 17 Cont 83 QZA_Intlpbck1 3
7 16 Cont 84 QZA_Intlpbck2 3
7 15 Cont 85 QZA_memory 3
7 14 Cont 86 QZA_DMA 3
7 13 Cont 63 QDSS_any 3
7 12 Cont 63 QDSS_any 3
B 11 Cont DB Speed 1
7 10 Cont EC ASYNC 6, 1
7 09 Cont E8 SYNC 7, 1
C 08 Cont 52 SSC_Prog_timers 1
C 07 Cont 52 SSC_Prog_timers 1
C 06 Cont 53 SSC_TOY_Clock 1
C 05 Cont C1 SSC_RAM_Data 1
B 04 Cont 55 Interval_Timer 1
B 03 Cont 41 Board_Reset 1, 3
1
Field-replaceable unit key:
1 = KA52
2 = MS44
3 = Q22–bus option
4 = System power supply
5 = SCSI device or 2 devices with same target id
6 = ASYNC option board
7 = COMM option board (SYNC)
8 = SHAC option board
5.3.1 FE Utility
In addition to the diagnostic console display and the LED code, the FE utility
dumps the diagnostic state to the console (Example 5–12). This state indicates
the major and minor test code of the test that failed, the 10 parameters
associated with the test, and additional diagnostic state information.
System Troubleshooting and Diagnostics 5–47