User`s guide
System Troubleshooting and Diagnostics
5.2 Product Fault Management and Symptom-Directed Diagnosis
Figure 5–8 Trigger Flow for the VAXsimPLUS Monitor
Entry type received
EMB$C_SE?
(Soft Error Interrupt)
LOGGING REASON
<03:00>=2?
SYSTAT<09>=1?
Hard Trigger
Soft Trigger
LOGGING REASON
<03:00>=1?
LOGGING REASON
<03:00>=4?
SYSTAT<08>=1?
SYSTAT<09>=1?
SYSTAT<00>=0?
SYSTAT<00>=1?
Y
YN
Y
Y
NN
N
N
N
N
Y
Y
Y
Y
N
Y
MLO-008656
as in Table 5-3
SICL Service
Request
VAXsimPLUS triggering notifies the customer and Services using three
message types: HARD, SOFT, and SICL Service Request. Each message
contains the single STARS article theory number, as well as the SYSTAT or
LOGGING REASON state. In addition, the SICL Service Request will have a
Merged Error Log (MEL) datafile appended. Both hard and soft triggers will
generate SICL Service Request messages.
5–34 System Troubleshooting and Diagnostics