User`s guide
System Troubleshooting and Diagnostics
5.2 Product Fault Management and Symptom-Directed Diagnosis
Example 5–6 Error Log Entry Indicating Correctable ECC Error
V A X / V M S SYSTEM ERROR REPORT COMPILED 21-NOV-1991 16:55:58
PAGE 1.
******************************* ENTRY 1. *******************************
ERROR SEQUENCE 2. LOGGED ON: SID 13001401
DATE/TIME 27-SEP-1991 09:51:13.98 SYS_TYPE 03110A01
SYSTEM UPTIME: 0 DAYS 00:05:06
SCS NODE: OMEGA1 VAX/OpenVMS V5.5-2
CORRECTABLE MEMORY ERROR KA52 CPU Microcode Rev # 1. CONSOLE FW REV# 1.1
Standard Microcode Patch Patch Rev # 10.
REVISION 00000000
SYSTAT 00000040
FLAGS 00000008
memory sbe reduction subpacket
MEMORY SBE REDUCTION SUBPACKET
LOGGING REASON 00000004
shutdown
PAGE MAPOUT CNT 00000000
MEMCON 000FFD01
MEMORY CONFIGURATION:
MS44-AA SIM Memory Module (4MB) Loc 0A
MS44-AA SIM Memory Module (4MB) Loc 0B
MS44-AA SIM Memory Module (4MB) Loc 0C
MS44-AA SIM Memory Module (4MB) Loc 0D
_Total memory = 16MB
_sets enabled = 000000001
MEMORY ERROR STATUS:
SIMM MEMORY MODULES: LOCATIONS 0A & 0B
Set = 0(X)
Bank = A
VALID ENTRY CNT 00000001
1.
CURRENT ENTRY 00000000
0.
MEMORY CRD ENTRY 1.
FOOTPRINT 00000073
(continued on next page)
System Troubleshooting and Diagnostics 5–25