Example 5–3 Error Log Entry Indicating Uncorrectable ECC Error
V A X / V M S SYSTEM ERROR REPORT COMPILED 6-NOV-1991 10:16:49
PAGE 25.
******************************* ENTRY 13. *******************************
ERROR SEQUENCE 2. LOGGED ON: SID 13001401
DATE/TIME 4-OCT-1991 09:14:29.86 SYS_TYPE 03110A01
SYSTEM UPTIME: 0 DAYS 00:01:39
SCS NODE: OMEGA1 VAX/OpenVMS V5.5-2
INT54 ERROR KA52 CPU Microcode Rev # 1. CONSOLE FW REV# 1.1
Standard Microcode Patch Patch Rev # 10.
REVISION 00000000
SYSTAT 00000601
ATTEMPTING RECOVERY
PAGE MARKED BAD
PAGE REPLACED
FLAGS 00000006
memory subpacket
KA52 subpacket
KA52 REGISTER SUBPACKET
BPCR ECC80000
.
.
.
MESR 80006800
UNCORRECTABLE MEMORY ECC ERROR
ERROR SUMMARY
MEMORY ERROR SYNDROME = 06(X)
.
.
.
MEAR 02FFDC00
main memory error address = 0BFF7000
ndal commander id = 00(X)
.
.
.
IPCR0 00000020
LOCAL MEMORY EXTERNAL ACCESS ENABLED
MEMORY SUBPACKET
MEMCON 000FFFF02
MEMORY CONFIGURATION:
MS44-AA SIM Memory Module 4 MB location 1E
MS44-AA SIM Memory Module 4 MB location 1F
MS44-AA SIM Memory Module 4 MB location 1G
MS44-AA SIM Memory Module 4 MB location 1H
_total memory = 16MB
(continued on next page)