5.2 Product Fault Management and Symptom-Directed Diagnosis
Example 5–1 (Cont.) Error Log Entry Indicating CPU Error
BPCR ECC80024
.
.
.
TBSTS 800001D3
LOCK SET
TRANSLATION BUFFER DATA PARITY ERROR
em_latch invalid
s5 command = 1D(X)
valid Ibox specifier ref. error stored
.
.
.
CESR 00000000
.
.
.
DSER 00000000
.
.
.
IPCR0 00000020
LOCAL MEMORY EXTERNAL ACCESS ENABLED
Note
Ownership (O-bit) memory correctable or fatal errors (MESR <04> or
MESR <03> of the processor Register Subpacket set equal to 1) are
processor module errors, NOT memory errors.
Example 5–2 SHOW ERROR Display Using the OpenVMS Operating System
$ SHOW ERROR
Device Error Count
CPU 1
MEMORY 1
PAB0: 1
PAA0: 1
PTA0: 1
RTA2: 1
$