Example 5–1 Error Log Entry Indicating CPU Error
V A X / V M S SYSTEM ERROR REPORT COMPILED 14-JAN-1992 18:55:52
PAGE 1.
******************************* ENTRY 1. *******************************
ERROR SEQUENCE 11. LOGGED ON: SID 13001401
DATE/TIME 27-SEP-1991 14:40:10.85 SYS_TYPE 03110A01
SYSTEM UPTIME: 0 DAYS 00:12:12
SCS NODE: OMEGA1 VAX/OpenVMS V5.5-2
MACHINE CHECK KA52 CPU Microcode Rev # 1. CONSOLE FW REV# 1.1
Standard Microcode Patch Patch Rev # 10.
REVISION 00000000
SYSTAT 00000001
ATTEMPTING RECOVERY
FLAGS 00000003
machine check stack frame
KA52 subpacket
STACK FRAME SUBPACKET
ISTATE_1 80050000
MACHINE CHECK FAULT CODE = 05(x)
Current AST level = 4(X)
ASYNCHRONOUS HARDWARE ERROR
.
.
.
PSL 04140001
c-bit
executing on interrupt stack
PSL previous mode = kernel
PSL current mode = kernel
first part done set
KA52 REGISTER SUBPACKET