Service manual
3.8.1 <REFERENCE>(xyp) Self-Test — RBD 0
RBD 0 is equivalent to the <REFERENCE>(xyp) power-up
self-tests.
Example 3–3: <REFERENCE>(xyp) Self-Test RBD 0
>>> ! Console program prompt.
>>> T/R ! Command to enter RBD monitor program.
RBD3> ! RBD monitor prompt, where 3 is the hexa-
! decimal node number of the boot processor.
RBD3> START 0 /TRACE/HE ! Runs the KA62B self-test on boot processor
! Trace prints each test number; halt on error
! Test results written to the console terminal:
;XCPST 6.0
; T0001 T0002 T0003 T0004 T0005 T0006 T0007 T0008 T0009 T0010
; T0011 T0012 T0013 T0014 T0015 T0016 T0017 T0018 T0019 T0020
; T0021
1
; F
2
3 8001 1
3
; HE XDEV_ERR 1 T0021
1
; 21 00000000 00000001 00000000 00001420 1FFD074C 00040CD0 02
In the example above:
1
test 21 failed,
2
F indicates failure, and
3
the
diagnostic ran for one pass.
Table 3–4: <REFERENCE>(xyp) Power-Up Test — RBD 0
Test Function
T0001 <REFERENCE>(xyp) ROM test
T0002 SSC Base Address Register test
T0003 SSC RAM test
T0004 SSC Configuration Register test
T0005 SSC Bus Timeout test
T0006 SSC Programmable Address Decode test
T0007 KA62B CSR1 test
T0008 SSC Output Port test
3–26 VAX 6000 Models 300 and 400 Service Manual