Service manual
Example 2–14: Sample VAX/DS Session (Model 400 Only), Part 3 of 3
>>> CLEAR EXCEPTION
6
XBER = 00000041 ! no error bits set
XFADR = 61880008 ! no error bits set
RCSR = 01240001 ! no error bits set
>>> SHOW CONFIGURATION
7
Type Rev
1+ KA64A (8082) 0007
3+ KA64A (8082) 0007
A+ MS65A (4001) 0002
B+ MS65A (4001) 0002
E+ DWMBB/A (2002) 0001
XBI E
1+ DWMBB/B (210F) 000A
2+ CIBCA (0108) 41C1
4+ KDB50 (010E) 0F1C
5+ DMB32 (0109) 210B
6+ TBK70 (410B) 0307
8+ DEBNI (0118) 0100
>>> CLEAR EXCEPTION
8
XBER = 8001B041 ! error bits set
XFADR = 61900000 ! error bits set
RCSR = 012C0011 ! error bits set
>>> CONTINUE
9
! No errors seen DS> appears
DS>
DS> ^P
?02 External halt (CTRL/P, break, or external halt)
PC = 0002704A
PSL = 00000204
KSP = 0004D210
>>> SHOW CONFIGURATION
.
.
.
>>> CONTINUE
10
! Errors seen before DS> appears
?? Unexpected trap or interrupt thru SCB vector 0060
PC at error: 0002704A(X)
PSL at error: 00000004(X) ; CUR=KERNEL,PRV=KERNEL,IPL=00(X),Z
User return PC: none found!
DS> CONTINUE
.. Continuing from 0002704A
DS>
2–40 VAX 6000 Models 300 and 400 Service Manual