Service manual
2.4.3 Sample VAX/DS Session
When you run the VAX/DS programs, run the system
autosizer program EVSBA first. This program, which takes
several minutes to execute, will save you time as you proceed
with other tests. Certain conditions cause the generation of
an unexpected trap or interrupt. Use the method shown to
avoid these conditions.
Example 2–12: Sample VAX/DS Session, Part 1 of 3
>>> SET BOOT DIAG /XMI:B /R5:10 DUA0 !booting through a KDM70
>>> BOOT DIAG
1
[self-test results print]
Loading system software.
VAX DIAGNOSTIC SOFTWARE
PROPERTY OF
DIGITAL EQUIPMENT CORPORATION
***CONFIDENTIAL AND PROPRIETARY***
Use Authorized Only Pursuant to a Valid Right-to-Use License
Copyright, Digital Equipment Corporation, 1990. All Rights Reserved.
DIAGNOSTIC SUPERVISOR. ZZ-ERSAA-14.X-NNNN 1-JAN-1990 12:01:45
DS> RUN EVSBA
2
.. Program: EVSBA - AUTOSIZER level 3 X6.6, revision 6.6, 3 tests,
at 17:52:20.21.
.. End of run, 0 errors detected, pass count is 1,
time is 31-DEC-1989 17:55:07.02
2–36 VAX 6000 Models 300 and 400 Service Manual