Service manual
Example 2–9 (Cont.): Booting the Diagnostic Supervisor over the
Ethernet
#2
NSS_SYSDISK
ESS_08002B15FCE1
08-00-2B-15-FC-E1
#3
6000_DIAG_A
ESS_08002B15FCE1
08-00-2B-15-FC-E1
Enter a number =>3
5
[Diagnostic Supervisor Banner prints]
DS>
After placing a CDROM cartridge labeled 6000_DIAG_* in a CD server on
the network, your system can access and boot the Diagnostic Supervisor
from the Ethernet.
1
At the console prompt enter a boot command identifying a path to the
CD server.
Should the Ethernet be attached directly to the XMI through a DEMNA,
you will not need the /BI qualifier and you will need to change the device
name to EXnn.
R5 = 110 sets two flags for VMB. Bit 4 specifies the Diagnostic
Supervisor. Bit 8 prompts for a secondary loader.
2
At the prompt, "Filename" type ISL_LVAX — the secondary loader. The
system loads software and identifies various functions available.
3
At the prompt, "Enter a function Id value:" enter a 3 to Choose Service.
4
Assuming you do not know the Service Name or number, at the "=>"
prompt enter a 1 to Find Services, otherwise enter a 2.
The available services are then located and shown. You should see the
name of the CD you just put into the CD server.
5
At the "Enter a number =>" prompt, enter the number of the server
that has the CD with the Diagnostic Supervisor on it. The Diagnostic
Supervisor then boots.
Diagnostics 2–33