Service manual

2.3.8 Running ROM-Based Diagnostics on VAXBI Devices
Some VAXBI devices can be tested from the console terminal
with their on-board ROM-based diagnostics. The Z console
command is used to send commands to these VAXBI nodes.
Example 2–8: VAXBI RBD Session
>>> SHOW CONFIGURATION
1
Type Rev
1+ <REFERENCE>(XRP) (8082) 0007
A+ MS65A (4001) 0002
E+ DWMBB/A (2002) 0001
XBI E
1+ DWMBB/B (210F) 000A
5+ DMB32 (0109) 210B
6+ DEBNI (0118) 0100
7+ KDB50 (010E) 0F1C
8+ TBK70 (410B) 0307
>>> Z/BI:6 E
2
?33 Z connection successfully started
T/R
3
RBD6> ST 0/TR
4
;DEBNI_ST 1.02
; T01 T02 T03 T04 T05 T06 T07 T08
; P 6 0118 00000020
;00000000 00000000 00000000 00000000 00000000 00000000 00000000
; PUDR: FFFFxxxx
RBD6> QUIT
5
^P
?31 Z connection terminated by ^P
>>> Z/BI:8 E
6
?33 Z connection successfully started
T/R
RBD8> ST 0/TR
;T1035_St 1.00
Example 2–8 Cont’d on next page
2–28 VAX 6000 Models 300 and 400 Service Manual