Service manual

with the /T=n:m qualifier, you run a range of tests. To terminate /P=n, enter
CTRL/C, CTRL/Z, or CTRL/Y. After entering one of these control characters,
a summary reports prints out and the RBD monitor prompt returns.
/QV selects the quick verify version of any selected test that supports this
mode.
/T=n[:m] selects individual tests (/T=n) or a range of tests (/T=n:m) where
n and m are decimal numbers. For example, to run tests T0005 through
T0008, use /T=5:8. If no /T qualifier is used, the diagnostic runs its default
suite of tests.
/TR prints each test number as it is completed. This qualifier allows you to
trace the progress of the diagnostic as it runs. Without the /TR qualifier,
just the summary line is printed.
For both the <REFERENCE>(xyp) and the <REFERENCE>(XRP) a single
parameter field can be appended to the START command string to control
aspects of the diagnostic that are not covered by the qualifiers. The
parameter must be appended after any qualifiers and separated from them
by a space. The format of the parameter field is 4 hex characters. The use
of a parameter field is implementation specific.
Diagnostics 2–17