Service manual
2.3.1 ROM-Based Diagnostic Programs
Table 2–4 and Table 2–5 lists the diagnostic programs
available for both VAX 6000 Model 300 and Model 400
systems.
Table 2–4: ROM-Based Diagnostic Programs for KA62B
RBD
Program
Test
Totals
Default
(Power-Up)
Default
(Callable) Description
0 34 34 34 Runs CPU tests
1 20 20 20 Runs CPU/memory interaction tests
2 26 21 20 Runs DWMBB tests
3 12 0 7 Sizes and runs additional tests on
main memory
4 8 0 0 Miscellaneous tests of second-level
cache
Table 2–5: ROM-Based Diagnostic Programs for KA64A
RBD
Program
Test
Totals
Default
(Power-Up)
Default
(Callable) Description
0 37
49
37
49
37
49
Runs CPU tests
Runs scalar and vector tests
1 13
17
12
16
13
17
Runs CPU/memory interaction tests
Runs scalar/vector CPU/memory in-
teraction tests
2 26 20 20 Runs DWMBB tests
3 12 0 7 Sizes and runs additional tests on
main memory
2–10 VAX 6000 Models 300 and 400 Service Manual