Table B–2 (Cont.): Model 400 Standard Console Error Mes-
sages
Error Message Meaning
?5F EEPROM header version mismatch. Processors have different versions of EEP-
ROMs.
?61 EEPROM header or area has bad
format.
All or part of the EEPROM contains in-
consistent data and is probably cor-
rupted. Reload the EEPROM from the TK
tape.
?62 Illegal node number. The specified node number is invalid.
?63 Unable to locate console tape device. The console could not locate the I/O
adapter that controls the TK tape.
?64 Operation only applies to secondary
processors.
The command can only be directed at a
secondary processor.
?65 Operation not allowed from secondary
processor.
A secondary processor cannot perform this
operation.
?66 Validation of EEPROM tape image failed. The image on tape is corrupted or
is not the result of a SAVE EEP-
ROM command. The image cannot be re-
stored.
?67 Read of EEPROM image from tape failed. The EEPROM image was not success-
fully read from tape.
?68 Validation of local EEPROM failed. For a PATCH EEPROM operation, the
EEPROM must first contain a valid im-
age before it can be patched. For a RE-
STORE EEPROM operation, the im-
age was written back to EEPROM
but could not be read back success-
fully.
?69 EEPROM not changed. The EEPROM contents were not changed.
?6A EEPROM changed successfully. The EEPROM contents were success-
fully patched or restored.
?6B Error changing EEPROM. An error occurred in writing to the EEP-
ROM. The EEPROM contents may be cor-
rupted.
?6C EEPROM saved to tape successfully. The EEPROM contents were success-
fully written to the TK tape.
?6D EEPROM not saved to tape. The EEPROM contents were not com-
pletely written to the TK tape.
B–8 VAX 6000 Models 300 and 400 Service Manual