Service manual

Table A–2 (Cont.): Model 300 Standard Console Error Mes-
sages
Error Message Meaning
?5E EEPROM header version mismatch. The primary and a secondary proces-
sor have different versions of the EEP-
ROM. The requested operation can-
not be performed.
?5F Bad transfer length. The primary processor attempted to send
EEPROM data to a secondary proces-
sor using an invalid length.
?60 EEPROM header or area has
bad format.
All or part of the EEPROM contains in-
consistent data and is probably cor-
rupted. Reload the EEPROM from the TK
tape.
?61 Illegal node number. The specified node number is invalid.
?62 Unable to locate console tape device. The console could not locate the I/O
adapter that controls the TK tape.
?63 Operation only applies to secondary
processors.
The command can only be directed at a
secondary processor.
?64 Insufficient memory to buffer EEPROM
image.
The SAVE, RESTORE, and PATCH EEP-
ROM commands require working mem-
ory, but not enough was found.
?65 Validation of EEPROM tape image failed. The image on tape is corrupted or
is not the result of a SAVE EEP-
ROM command. The image cannot be re-
stored.
?66 Read of EEPROM image from tape failed. The EEPROM image was not success-
fully read from tape.
?67 Validation of local EEPROM failed. For a PATCH EEPROM operation, the
EEPROM must first contain a valid im-
age before it can be patched. For a RE-
STORE EEPROM operation, the im-
age was written back to EEPROM
but could not be read back success-
fully.
?68 EEPROM not changed. The EEPROM contents were not changed.
?69 EEPROM changed successfully. The EEPROM contents were success-
fully patched or restored.
A–8 VAX 6000 Models 300 and 400 Service Manual