Service manual

Table A–2 (Cont.): Model 300 Standard Console Error Mes-
sages
Error Message Meaning
?46 Insufficient working memory for normal op-
eration.
Less than 256 Kbytes per processor of
working memory were found. There is in-
sufficient memory for the console to func-
tion normally or for the operating sys-
tem to boot.
?47 Uncorrectable memory errors—long mem-
ory test must be performed.
A memory array contains an unrecov-
erable error. The console must per-
form a slow test to locate all the failing lo-
cations.
?49 Memories not interleaved due to
uncorrectable errors:
The listed arrays would normally have
been interleaved (by default or explicit re-
quest). Because one or more of them con-
tained unrecoverable errors, this inter-
leave set will not be constructed.
?4A Internal logic error in console. The console encountered a theoreti-
cally impossible condition.
?4B Invalid node for Z command. The target of a Z command must be a CPU
or an I/O adapter and must not be the pri-
mary processor.
?4C Invalid node for new primary. The SET CPU command failed when at-
tempting to make the specified node the
primary processor.
?4D Specified node is not a processor. The specified node is not a processor, as re-
quired by the command.
?4E System serial number has not been
initialized.
No CPU in the system contains a valid
system serial number.
?4F System serial number not initialized on
primary processor.
The primary processor has an uninitial-
ized system serial number. All other pro-
cessors in the system contain a valid se-
rial number.
?50 Secondary processor returned bad
response message.
A secondary processor returned an un-
intelligible response to a request made
by the console on the primary proces-
sor.
?51 ROM revision mismatch. Secondary
processor has revision x.y.
The revision of console ROM of a sec-
ondary processor does not match the pri-
mary.
A–6 VAX 6000 Models 300 and 400 Service Manual