Table A–2 (Cont.): Model 300 Standard Console Error Mes-
sages
Error Message Meaning
?2D For Secondary Processor n This message is a preface to sec-
ond message describing some error re-
lated to a secondary processor. This mes-
sage indicates which secondary proces-
sor is involved.
?2E Specified node is not an I/O adapter. The referenced node is incapable of per-
forming I/O or did not pass its self-
test.
?30 Write to Z command target has timed out. The target node of the Z command is not
responding.
?31 Z connection terminated by ^P. A CTRL/P was typed on the key-
board to terminate a Z command.
?32 Your node is already part of a Z connec-
tion.
You cannot issue a Z command while exe-
cuting a Z command.
?33 Z connection successfully started. You have requested a Z connection to a
valid node.
?34 Specified target already has a Z connec-
tion.
The target node was the target of a previ-
ous Z connection that was improperly ter-
minated. Reset the system to clear this
condition.
?36 Command too long. The command length exceeds 80 charac-
ters.
?37 Explicit interleave list is bad.
Configuring all arrays uninterleaved.
The list of memory arrays for ex-
plicit interleave includes no nodes that
are actually memory arrays. All ar-
rays found in the system are config-
ured.
?38 Waiting for a CR to terminate the com-
mand.
The command has not yet been is-
sued by a carriage return.
?39 Console patches are not useable. The console patch area in EEPROM
is corrupted or contains a patch revi-
sion that is incompatible with the con-
sole ROM.
?3B Error encountered during I/O opera-
tion.
An I/O adapter returned an error status
while the console boot primitive was per-
forming I/O.
A–4 VAX 6000 Models 300 and 400 Service Manual