Example 6–6: RBD 3 Parameter
RBD3> ST3/TR/T=11:12/C 0A ! Runs <REFERENCE>(XMA2) RBD tests
! T0011 and T0012 from RAM on the
! the memory module in slot A. Confirm
! destructive memory test switch (/C)
! is required on these tests.
;XMA_RBD 3.00
; T0011 T0012
[RBD status messages are printed every two minutes;
use the /DS qualifier in the command string to inhibit
these messages.]
; P 3 8082 1
;00000000 00000000 00000000 00000000 00000000 00000000 00000000
RBD3> QUIT ! Exit from RBD monitor program
?06 Halt instruction executed in kernel mode.
PC = 200601D8
PSL = 041F0604
ISP = 201405B4
>>> ! Console prompt returns
In Example 6–4 note the status message in the display (
1
). The message
fields are as follows:
S = Status message
3 = Node from which the RBD is running
8082 = Device type of node from which RBD is running
1 = Pass 1
XX = Undefined
NO_XMA2 = RBD does not perform parts of test 8 on MS65A memories
09 = Node where MS65A resides
T0008 = Test 8 produced the status message
The RBD completes with the normal pass/fail message. Only test 8, the
Interlock Lock Logic Test, behaves this way; all other tests are run on both
MS62As and MS65As.
MS65A Memory 6–23