Service manual
3.8.3 Second-Level Cache Test — RBD 4
RBD 4 tests the second-level cache. Note that no tests are
run by default.
Example 3–5: Second-Level Cache Test RBD 4
>>> T/R ! Command to enter RBD monitor program
RBD1> ! RBD monitor prompt, where 1 is the
! hexadecimal node number of the processor
! that is currently receiving your input
RBD1> ST4/T=1:2/TR ! Specifically asks for tests 1 and 2 to
! be run with trace enabled
;SLCRBD 6.0
; T0001 ! Test 1 started
1 3
; S 1 8001 1 ! Status message for test 1
; XX SL_CACHE XX T0001
;00000000 00040000 00000000 00000000 00000000 00000000 00000000 00000000
! Print message showing current
! address and ending address
; T0002 ! Test 2 started
1 3
; S 1 8001 1 ! Status message for test 2
; XX SL_CACHE XX T0002
;00000000 01000000 00000000 00000000 00000000 00000000 00000000 00000000
! Print message showing current
! address and ending address.
;00000042 00000000 00000000 00000000 00000000 00000000 00000000 00000000
! Print message showing the
! number of cache hits
2 3
; P 1 8001 1
;00000000 00000000 00000000 00000000 00000000 00000000 00000000
RBD1> QUIT ! Exit the RBD monitor
3–32 VAX 6000 Models 300 and 400 Service Manual