Configuration Software on DEC VAX and DEC AXP Systems (Revision B — May 1998)
Message WARNING - CHIP should be installed before ENVOX
Description Ensure CHIP is installed before installing ENVOX software.
Message UIC is already in use
Description Enter a valid unique UIC.
Message UIC is not a valid UIC
Description The UIC must be in the form, group,member, where group and member
are OCTAL numeric values in the range; group = [0 to 37776] and
member = [0 to 177776].
Message envox & envoxsupport UICs are the same
Description Enter unique UICs for envox and envoxsupport users.
Message The sybase stopserver symbol is undefined
Description Verify that the stopserver symbol is defined in
sybase_system:[sybase.install]sybase_manager.com.
Message The sybase server is not running.
Description Determine whether the server is running by examining the output from the
DCL command show system. If no sybase server process exists, then
restart the server by issuing the DCL command startserver. If the server
fails to start, determine the cause of the failure by examining
sybase_system:[sybase.install]start_sybase.out
Message Device tape_device does not exist
Description The entered tape device does not exist.
Message tape_device is not a valid tape device
Description The device class of the tape device must be a tape or a disk.