Technical data
X25L3 CIRCUIT
X25L3 CIRCUIT
Format
"X25L3 CIRCUIT *"
Description
This tracepoint traces all X25 packet level PDUs transmitted and received by the
X25 Protocol Module. Tracing can be enabled for all circuits only. Table B–4 lists
the events that are recognized at this tracepoint.
Table B–4 X.25L3 CIRCUIT Trace Events for VAX P.S.I.
Trace Event Description
RX Receive
TX Transmit
Example
$ TRACE START/LIVE "X25L3 CIRCUIT */PROTOCOL=L3
produces the following output:
-----------+----+-----+<--------Packet-------->+
Time |Evnt|Data |Chn Q Type P P |
hh mm ss cc| |Size | M R/S R/S |
-----------+----+-----+<---------------------->+
15:05:04.35|RX | 3|001 CALLC |
15:05:04.37|RX | 14|001Q DATA 0/0 |
15:05:04.38|RX | 4|001 DATA 0/1 |
15:05:04.48|TX | 3|001 RR 1/ |
15:05:04.76|TX | 3|001 RR 2/ |
15:05:04.90|TX | 14|001Q DATA 2/0 |
15:05:04.94|RX | 3|001 RR 1/ |
15:05:05.19|RX | 6|001 DATA 1/2 |
15:05:05.22|TX | 3|001 RR 3/ |
15:05:05.24|RX | 51|001 DATA 1/3 |
15:05:05.25|RX | 5|001 DATA 1/4 |
15:05:05.33|TX | 3|001 RR 4/ |
15:05:05.34|TX | 3|001 RR 5/ |
15:05:05.39|RX | 15|001 DATA 1/5 |
15:05:05.42|TX | 3|001 RR 6/ |
B–6 VAX P.S.I. Tracepoints