Owner`s manual
B.2 Determining Failing Test from LEDs
When self-test fails, the red LEDs on the KA65A contain
the failing test number. Check the state of other module
LEDs to determine the failing RBD and device, as shown in
Table B–1.
Table B–1: KA65A Status LEDs
KA65A LEDs
Diagnostic and Self-Test
Yellow Red Test Number Device Failing Line
FV64A Yellow LED OFF
OFF 1–45 Power-up self-test (RBD 0)
T0001–T0045
KA65A STF
ON 46–57 Power-up self-test (RBD 0)
T0046–T0057
FV64A STF
OFF 61–82 CPU/memory test - Memory 1
(RBD 1) T0001–T0022
KA65A, FV64A, or
MS65A 1 (module
with lowest XMI
node number)
ETF
ON 79–82 CPU/memory test - Memory 1
(RBD 1) T0079–T0082
FV64A ETF
OFF 83 CPU/memory test - Memory 2
T0003
(equivalent to ST1/T=3)
MS65A 2 ETF
OFF 84 CPU/memory test - Memory 3 MS65A 3 ETF
OFF 85 CPU/memory test - Memory 4 MS65A 4 ETF
OFF 86 CPU/memory test - Memory 5 MS65A 5 ETF
OFF 87 CPU/memory test - Memory 6 MS65A 6 ETF
OFF 88 CPU/memory test - Memory 7 MS65A 7 ETF
OFF 89 CPU/memory test - Memory 8 MS65A 8 ETF
B–4 VAX 6000: Installing Model 500 Processors