User`s manual

Figure 5.5 Using Both Set Points on One Inspection Result
Discrete outputs = N.C. 1
Set point A
= 38% olFOV
Set point B
=42% ofFOV
1 Dkcreteoutput A A
I
1
Dkcrete output A
= closed
)
I
I
= open
I
I
I
I
Dkcrete output B
1
I
Discrete outpot B
= closed
I
-
)
I
I
= open
Output B (inverted)
:
I
I-
Output B (inverted) l
q open
: Both discrete outputs :
= closed
+ areopen +
0 when result is between 1
I
38% and428
You can select one of the following set point methods:
1. Single set points - This is the default setting, and it
causes each set point to operate on its corresponding
inspection result. Thus, Set Point A operates on result
A, and Set Point B operates on result B.
2. Both set points for Result A - This setting causes both
set points to operate on inspection result A.
3. Both set points for Result B -This setting causes both
set points to operate on inspection result B.
When you highlight the Set Point Method field, the Set
Point Method Menu appears on the screen, as shown in
Figure 5.6.
Figure 5.6 Set Point Method Menu
Single set points
Both set points for Result A
Both set points for Result B
5-12